Test For A Short Circuit
Table 1
Troubleshooting Test Steps Values Results
1. Identify Short Circuit.
A. Identify the connectors and the wire numbers of the suspect circuits. Use the Electrical System Schematic of the machine to identify the circuits.
B. Turn the key start switch and the disconnect switch to OFF.
C. Disconnect the component and the ECM from the wiring harness.
D. At the machine harness connector for the ECM, place one of the multimeter probes on the contact of the suspect wire.
E. Use the other multimeter probe to check the resistance across all other contacts in the connectors of the ECM and frame ground.
The resistance is greater than 5K Ω for all the readings. OK - The harness circuits are correct.
STOP
NOT OK - The resistance is less than 5 Ω. There is a short in the machine harness. The short is between the suspected wire and the wire with the lowest resistance measurement.
Repair: Repair or replace the machine harness.
Note: A resistance that is greater than 5 Ω but less than 5K Ω would indicate a loose connection or a corroded connection in the circuit. A resistance measurement that is greater than 5K Ω would indicate an open in the circuit.
STOP
Table 1
Troubleshooting Test Steps Values Results
1. Identify Short Circuit.
A. Identify the connectors and the wire numbers of the suspect circuits. Use the Electrical System Schematic of the machine to identify the circuits.
B. Turn the key start switch and the disconnect switch to OFF.
C. Disconnect the component and the ECM from the wiring harness.
D. At the machine harness connector for the ECM, place one of the multimeter probes on the contact of the suspect wire.
E. Use the other multimeter probe to check the resistance across all other contacts in the connectors of the ECM and frame ground.
The resistance is greater than 5K Ω for all the readings. OK - The harness circuits are correct.
STOP
NOT OK - The resistance is less than 5 Ω. There is a short in the machine harness. The short is between the suspected wire and the wire with the lowest resistance measurement.
Repair: Repair or replace the machine harness.
Note: A resistance that is greater than 5 Ω but less than 5K Ω would indicate a loose connection or a corroded connection in the circuit. A resistance measurement that is greater than 5K Ω would indicate an open in the circuit.
STOP
Parts block Caterpillar catalog:
4Z8789
BLOCK
Caterpillar
Caterpillar
4Z8764
BLOCK-GUIDE
Caterpillar
Caterpillar
4Z8761
BLOCK
Caterpillar
Caterpillar
4Z8702
BLOCK-SUPPORT
Caterpillar
Caterpillar
4Z8697
BLOCK-SUPPORT
Caterpillar
Caterpillar
4Z8637
BLOCK-STOP
Caterpillar
Caterpillar
5012705
BLOCK-TAP
Caterpillar
Caterpillar
5012606
BLOCK-MOUNTING
Caterpillar
Caterpillar
5009053
BLOCK-CLAMP
Caterpillar
Caterpillar
5003620
BLOCK-COVER
Caterpillar
Caterpillar
5003595
BLOCK-SPRAY
Caterpillar
Caterpillar
4Z9299
BLOCK-STOP
Caterpillar
Caterpillar