615011E001 HIGH PRESSURE FUEL SYSTEM (Reference) Caterpillar parts
Rating:
Alternative (cross code) number:
CA615011E001
615011-E001
615011E001
CA615011E001
615011-E001
615011E001
Information:
Illustration 1 g00951552
Schematic of the Control Valve (Programmable Hydraulic System)This diagnostic code is associated with module 2. The FMI 06 means that the ECM has determined that one or more of the pilot solenoid drivers is grounded or experiencing an over current condition.The possible causes of this diagnostic code are listed:
Module 2 on the PHS Valve SSV4 electronic control has failed.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1846 FMI 06 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:Note: The following responses may occur simultaneously or the responses could occur individually.
The boom raise function and the boom lower function will not work properly.
The fork rack function and the fork dump function will not work properly.Test Step 1. VERIFY SOFTWARE VERSIONNote: From SIS or the latest release of the CD for SIS check and record the latest software version for the machine electronic controls.
Verify the machine ECM has the latest software version loaded.
Verify that the valve ECM's have the latest software loaded.Expected Result:All of the software is up to date.Results:
OK - All of the software is up to date. Proceed to Test Step 2.
NOT OK - There is a more recent software release available.Repair: Flash all controls with the latest software release. Refer to Testing and Adjusting, "Electronic Control Module (ECM) - Flash Program". Stop.Test Step 2. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Clean the contacts of the harness connectors.
Reconnect all harness connectors.
Observe the status of the diagnostic code.
Operate the machine.
Observe the status of the diagnostic code.Expected Result:The diagnostic code is NO longer active.Results:
YES - The diagnostic code is NO longer active. The diagnostic code does not exist at this time. The initial diagnostic code was probably caused by a poor electrical connection and/or a short at one of the harness connectors that was disconnected and then reconnected. Resume normal machine operation. Stop.
NO - The diagnostic code has not been corrected. The PHS SSV4 module has failed.Repair: Replace the PHS Valve SSV4 control if the cause of the diagnostic code is not found. See Testing and Adjusting, "Electronic Control Module (ECM) - Flash Program". Stop.
Caterpillar SIS machinery equipment:
Caterpillar SIS
- CT15 ON HIGHWAY TRUCK ENGINE SJJ00001-UP » 615011-E001 HIGH PRESSURE FUEL SYSTEM
Caterpillar parts catalog:
Parts high Caterpillar catalog:
0858142
HIGH PRESSURE CUT OFF VALVE ASSY.
E110B, E120B
E110B, E120B
0990262
HIGH PRESSURE CUT OFF VALVE ASSY.
E110B, E120B
E110B, E120B
0964364
HIGH PRESSURE CUT OFF
E200B, EL240B
E200B, EL240B
0991632
HIGH PRESSURE CUT OFF VALVE ASSY.
E180, E240
E180, E240
8D2680
HIGH SPEED OIL CHANGE GROUP
637, 637B
637, 637B
1009939
HIGH POWER-
Caterpillar
Caterpillar
1009938
HIGH POWER-
Caterpillar
Caterpillar
1009937
HIGH POWER-
Caterpillar
Caterpillar
1009936
HIGH POWER-
Caterpillar
Caterpillar
0817258
HIGH TEMP WI
Caterpillar
Caterpillar
0787476
HIGH LOW SHI
Caterpillar
Caterpillar