Illustration 1 g01321550
Schematic of the Winch Spool In Solenoid (12 pin ECM connection)
Illustration 2 g02716744
Schematic of the Winch Spool In Solenoid (70 pin ECM connection)This diagnostic code is associated with the Winch Spool In Solenoid. The FMI 03 means that the ECM has determined that the voltage of the solenoid circuit is above normal.The possible causes of this diagnostic code are listed:
The energize circuit of the solenoid is shorted to the +battery circuit.
The ECM has failed. This is unlikely.Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1884 FMI 03 is active before performing this procedure.Note: Use a Digital Multimeter for the measurements in the procedure.System Response:A level 2 warning will be generated.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO THE +BATTERY CIRCUIT.
Turn the key start switch and the disconnect switch to the ON position.Note: Use a wire removal tool to remove the appropriate wires from the machine harness connector for the ECM.
Remove the wire for the solenoid signal (F869-PK) of the connector contact of the ECM.
Measure the voltage from the wire for the solenoid signal (F869-PK) to frame ground.
Remove the wire for the solenoid return (J807-BK) of the of the ECM.
Measure the voltage from the wire for the solenoid return (J807-BK) to frame ground.Expected Result:The voltage is 0 VDC.Results:
OK - The voltage is 0 VDC. There are no shorts in the wires. Proceed to test step 2.
NOT OK - There is a voltage present in a wire. The short is in the wire with a measured voltage. The machine harness has failed.Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the contacts and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the CID 1884 FMI 03 is active.Expected Result:The CID 1884 FMI 03 is active.Results:
YES - The CID 1884 FMI 03 is active. The problem has not been corrected. The ECM may have failed.Repair: If the cause of the problem is not found, contact the Technical Communicator for your dealership for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the ECM requires replacement, see Troubleshooting, "Electronic Control Module (ECM) - Replace".STOP
NO - The CID 1884 FMI 03 is not active. The problem does not exist at this time.Repair: The initial diagnostic code was probably caused by a poor electrical connection or a
Parts housing Caterpillar catalog:
4642415
HOUSING
Caterpillar
Caterpillar
4639197
HOUSING AS-
Caterpillar
Caterpillar
4639103
HOUSING
Caterpillar
Caterpillar
4639050
HOUSING AS
Caterpillar
Caterpillar
4636375
HOUSING AS
Caterpillar
Caterpillar
4636356
HOUSING
Caterpillar
Caterpillar
4652048
HOUSING-
Caterpillar
Caterpillar
4649467
HOUSING-SEAL
Caterpillar
Caterpillar
4649464
HOUSING-
Caterpillar
Caterpillar
4647571
HOUSING
Caterpillar
Caterpillar
4646193
HOUSING
Caterpillar
Caterpillar
4646173
HOUSING
Caterpillar
Caterpillar