Rectifier and Capacitor Test
Measure the voltage at Terminal 22 (-) and Terminal 23 (+).
If the voltage at Terminal 22 (-) and Terminal 23 (+) is greater than 42 DCV, the rectifiers and the capacitor are OK. STOP.
If the voltage at Terminal 22 (-) and Terminal 23 (+) is less than 42 DCV, Power Supply Board 1 is bad. Contact the Caterpillar Large Engine Center (LEC) for information on obtaining repair parts. The Caterpillar LEC can be reached at the following locations. Phone: 765-448-2400, Fax: 765-448-2300, E-mail: applicationsupport, Internet: http://applicationsupport.cat.com.
Disconnect Wire 22 from Terminal 22. Disconnect Wire 23 from Terminal 23. Measure the voltage at Wire 22 (-) and Wire 23 (+).
If the voltage at Wire 22 (-) and Wire 23 (+) is greater than 42 DCV, the rectifiers and capacitor are OK. Reconnect Wire 22 and Wire 23. STOP.
If the voltage at Wire 22 (-) and Wire 23 (+) is less than 42 DCV, Power Supply Board 1 is bad. Contact the Caterpillar Large Engine Center (LEC) for information on obtaining repair parts. The Caterpillar LEC can be reached at the following locations. Phone: 765-448-2400, Fax: 765-448-2300, E-mail: applicationsupport, Internet: http://applicationsupport.cat.com.Power Supply Board 2 - Test
Measure the voltage at Terminal 21 (+) and Terminal 22 (-).
If the voltage at Terminal 21 (+) and Terminal 22 (-) is between
Measure the voltage at Terminal 22 (-) and Terminal 23 (+).
If the voltage at Terminal 22 (-) and Terminal 23 (+) is greater than 42 DCV, the rectifiers and the capacitor are OK. STOP.
If the voltage at Terminal 22 (-) and Terminal 23 (+) is less than 42 DCV, Power Supply Board 1 is bad. Contact the Caterpillar Large Engine Center (LEC) for information on obtaining repair parts. The Caterpillar LEC can be reached at the following locations. Phone: 765-448-2400, Fax: 765-448-2300, E-mail: applicationsupport, Internet: http://applicationsupport.cat.com.
Disconnect Wire 22 from Terminal 22. Disconnect Wire 23 from Terminal 23. Measure the voltage at Wire 22 (-) and Wire 23 (+).
If the voltage at Wire 22 (-) and Wire 23 (+) is greater than 42 DCV, the rectifiers and capacitor are OK. Reconnect Wire 22 and Wire 23. STOP.
If the voltage at Wire 22 (-) and Wire 23 (+) is less than 42 DCV, Power Supply Board 1 is bad. Contact the Caterpillar Large Engine Center (LEC) for information on obtaining repair parts. The Caterpillar LEC can be reached at the following locations. Phone: 765-448-2400, Fax: 765-448-2300, E-mail: applicationsupport, Internet: http://applicationsupport.cat.com.Power Supply Board 2 - Test
Measure the voltage at Terminal 21 (+) and Terminal 22 (-).
If the voltage at Terminal 21 (+) and Terminal 22 (-) is between
Caterpillar SIS machinery equipment:
Caterpillar SIS
G3508J Gas Compression Engine N8W00001-UP »
384-3602
IGNITION GP-GAS ENGINE
G3508 Gas Engine N8A00001-UP »
384-3602
IGNITION GP-GAS ENGINE
G3508 Gas Engine N8A00001-UP »
384-3602
IGNITION GP-GAS ENGINE
G3508 Gas Engine N8B00001-UP »
384-3602
IGNITION GP-GAS ENGINE
G3508 Gas Engine N8B00001-UP »
384-3602
IGNITION GP-GAS ENGINE
G3508B Gas Engine N8C00001-UP »
384-3602
IGNITION GP-GAS ENGINE
G3508B Gas Engine N8C00001-UP »
384-3602
IGNITION GP-GAS ENGINE