1694910 MOUNTING GP-SHEAR Caterpillar parts S115, VPS-35 MOUNTING
Rating:
Alternative (cross code) number:
CA1694910
169-4910
1694910
CA1694910
169-4910
1694910
SHEAR-MECHANICAL,
Information:
Illustration 1 g00772010
Schematic of the Auxiliary Solenoid The auxiliary solenoid must be installed by the customer.This is recorded when the ECM reads the voltage of the solenoid circuit as above normal (short to +battery).The possible causes of this diagnostic code are listed:
The harness is shorted.
The ECM has failed. This is unlikely.System Response:The machine response is listed:
All implement functions will be disabled.Note: Ensure that CID 1180 FMI 03 is active.Test Step 1. CHECK THE SIGNAL CIRCUIT FOR A SHORT.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness from the solenoid.
Disconnect the machine harness connectors J1 and J2 from the ECM.
At machine harness connector J2, measure the resistance from the solenoid signal contact J2-4 to all other J1 and J2 connector contacts. Expected Result:Each resistance should be greater than 5000 ohms.Results:
YES - Each resistance is greater than 5000 ohms. The machine harness is correct. Proceed to test step 2.
NO - There is a short in the machine harness. Repair: The short is between the signal contact J2-4 and the circuit with the low resistance measurement. Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the contacts and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Clear all inactive diagnostic codes.
Operate the machine.
Stop the machine and place the parking brake switch in the ON position.
Check if the diagnostic code for the solenoid is present.Expected Result:The diagnostic code for the solenoid is no longer present.Results:
YES - The diagnostic code is not present. The diagnostic code does not exist at this time. The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.STOP
NO - The diagnostic code has not been corrected.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. Also, recheck if the diagnostic code is active. If the cause of the diagnostic code is not found, replace the implement ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOP
Caterpillar SIS machinery equipment:
Caterpillar SIS
- S115 & S128 Mechanical Shears ADY00001-UP (MACHINE) » 169-4910 MOUNTING GP-SHEAR
- VPS-35 and VPS-45 Mechanical Shears BXA00001-UP (MACHINE) » 169-4910 MOUNTING GP-SHEAR
Caterpillar parts catalog:
Parts mounting Caterpillar catalog:
1698897
MOUNTING GP-SHEAR
S115, VPS-35
S115, VPS-35
1708275
MOUNTING GP-SHEAR
S115, VPS-35
S115, VPS-35
1708286
MOUNTING GP-SHEAR
S115, VPS-35
S115, VPS-35
1708288
MOUNTING GP-SHEAR
S115, VPS-35
S115, VPS-35
1708289
MOUNTING GP-SHEAR
S115, VPS-35
S115, VPS-35
1708290
MOUNTING GP-SHEAR
S115, VPS-35
S115, VPS-35
1843511
MOUNTING GP-SHEAR
S115, VPS-35
S115, VPS-35
1849823
MOUNTING GP-SHEAR
S115, VPS-35
S115, VPS-35