4645938 SFWR GP-A1000 Caterpillar parts SFWR
Rating:
Alternative (cross code) number:
CA4645938
464-5938
4645938
CA4645938
464-5938
4645938
Buy SFWR GP-A1000 4645938 Caterpillar genuine, new aftermarket tractor parts with delivery
Information:
open is a failure of an electrical circuit that results in no flow of electrical current. An open circuit is usually caused by failed electrical wires or a poor connection of electrical connectors. If an electrical wire or a connection is broken, the flow of electrical current through the circuit is interrupted. A normally closed circuit will have less than 5 ohms of resistance. The following procedure explains the test for an open circuit:ReferenceFor a complete electrical schematic, refer to Electrical System Schematic for the machine that is being serviced.TEST FOR AN OPEN CIRCUIT.
Identify the connectors and the wire numbers of the suspect circuits. Use the Electrical System Schematic of the machine to identify the circuits.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the components from the wiring harness.
At one of the disconnected harness connections, place a jumper wire from the contact of the suspect wire to frame ground.
At the other connector of the machine harness, use the multimeter probes to measure the resistance from the contact of the suspect wire to frame ground.Expected Result: The resistance is less than 5 ohms. OK - The resistance is less than 5 ohms. The harness circuit is correct.Stop. NOT OK - The resistance is greater than 5 ohms. There is an open in the machine harness.Repair: Repair the machine harness or replace the machine harness.Stop.
Identify the connectors and the wire numbers of the suspect circuits. Use the Electrical System Schematic of the machine to identify the circuits.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the components from the wiring harness.
At one of the disconnected harness connections, place a jumper wire from the contact of the suspect wire to frame ground.
At the other connector of the machine harness, use the multimeter probes to measure the resistance from the contact of the suspect wire to frame ground.Expected Result: The resistance is less than 5 ohms. OK - The resistance is less than 5 ohms. The harness circuit is correct.Stop. NOT OK - The resistance is greater than 5 ohms. There is an open in the machine harness.Repair: Repair the machine harness or replace the machine harness.Stop.
Parts sfwr Caterpillar catalog:
4645937
SFWR GP-A1000
Caterpillar
Caterpillar
4645936
SFWR GP-A1000
Caterpillar
Caterpillar
4645935
SFWR GP-A1000
Caterpillar
Caterpillar
4645934
SFWR GP-A1000
Caterpillar
Caterpillar
4645931
SFWR GP-A1000
Caterpillar
Caterpillar
4645926
SFWR GP-A1000
Caterpillar
Caterpillar
4645939
SFWR GP-A1000
Caterpillar
Caterpillar
4645940
SFWR GP-A1000
Caterpillar
Caterpillar
4645941
SFWR GP-A1000
Caterpillar
Caterpillar
4646052
SFWR GP-A3000
Caterpillar
Caterpillar
4646772
SFWR GP-A4007
Caterpillar
Caterpillar
4646903
SFWR GP-A1000
Caterpillar
Caterpillar