Which Generate This Code:This diagnostic code is recorded when the ECM reads the system voltage as being greater than 31.5 DCV for at least 2 seconds.The possible causes of this diagnostic code are listed:
A charging system component has failed.
The wiring of the machine harness has failed.
The ECM has failed. This is unlikely.System Response:When this diagnostic code is active, the control system will default to the "Auto Not Allowed" state.Test Step 1. CHECK THE CHARGING SYSTEM.
Turn the disconnect switch and the key start switch to the ON position.
View the status of the diagnostic code.Expected Result:The diagnostic code is NO longer active.Results:
YES - The diagnostic code is NO longer active. Proceed to test step 2.
NO - The diagnostic code remains active. Proceed to test step 3.Test Step 2. CHECK THE CHARGING SYSTEM AGAIN.
Start the engine.
View the status of the diagnostic code.Expected Result:The diagnostic code is NO longer active.Results:
YES - The diagnostic code is NO longer active. Watch for a recurrence.STOP
NO - The diagnostic code is active. The charging system is charging at an excessive voltage. Repair: Check the charging system. See Special Instruction, REHS0354, "Charging System Troubleshooting" for more information.STOPTest Step 3. CHECK THE BATTERY VOLTAGE.
The engine should not be running.
At the battery, measure the voltage of the battery.Expected Result:The voltage should measure less than 32 DCV.Results:
YES - The voltage measures less than 32 DCV. The ECM must be recording this diagnostic code incorrectly. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is NOT found, replace the ECM. See Troubleshooting, "Module - Replace".STOP
NO - The voltage measurement is greater than 32 DCV. The charging system is charging at an excessive voltage.Repair: Check the charging system.STOP

Caterpillar SIS machinery equipment:

Caterpillar SIS

Caterpillar parts catalog:

Caterpillar parts catalog
D6T Track-Type Tractor, XL VPAT, XW VPAT, LGP VPAT KTW00001-UP (MACHINE) POWERED BY C9.3 Engine
D6T Track-Type Tractor XL VPAT, XW VPAT, LGP VPAT AG900001-UP (MACHINE) POWERED BY C9.3 Engine


Parts tractor Caterpillar catalog:

Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.