AVSPARE.COM
parts catalog

TUBE A. 7B0147 - Caterpillar



7B0147 TUBE A. Caterpillar parts TUBE
Rating:
21
Alternative (cross code) number:
CA7B0147
7B-0147
7B0147
Caterpillar 7B0147 TUBE A.

Buy TUBE A. 7B0147 Caterpillar genuine, new aftermarket tractor parts with delivery

  For full view, you need register

Information:


Illustration 42 g00487241
Connect the "VIMS-PC" to the module. The message center should be in the background mode. The following items should be displayed on the display center: time, date and service hours. Use the keypad in order to enter the command "SVCSET" (782738). The message center will display the above display. Note: The display starts with current setting. The default setting is displayed on the message center when a new source has been loaded or a new configuration has been loaded. The previous example reflects the default setting of 1. "1-2 SNAPSHOT FULL".
Illustration 43 g00487242
Illustration 44 g00487243
Press the right arrow key in order to advance to next setting.
Illustration 45 g00487244
Press the right arrow key in order to advance to next setting.
Illustration 46 g00487245
Press the right arrow key in order to advance to next setting.
The arrow keys are used to move through the list of available settings. The "OK" key selects the desired setting. Note: If the arrow key is pressed again the list remains at the last setting. Press the left arrow key in order to move back through the settings .
Illustration 47 g00487244
Press the "OK" key in order to accept the setting when the desired "Service Lamp Setting" is displayed on the message center. The option that was selected is now the new service lamp mode. Note: The setting of the service lamp is set to option 4. The title of option 4 is "DAMAGE EVENTS ONLY". This setting will be used for all operations until one of the following events:
A new source is loaded.
A new configuration is loaded.
The backup battery is replaced.
The user selects a new setting with VIMS-PC. The VIMS-PC must be connected to the machine.The following table summarizes the service lamp behavior in the five settings of the lamp mode.
Table 2
Service Lamp Behavior
Lamp Setting Mode Damage Event Active Event 2nd Snapshot Full 1st Snapshot Full
1-2 Snapshot Full Flashing ON Flashes Every Five Minutes Flashes Every 10 Minutes
2 Snapshots Full Flashing ON Flashes Every Five Minutes OFF
No Snapshot Notice Flashing ON OFF OFF
Damage Events Only Flashing OFF OFF OFF
Never On OFF OFF OFF OFF