9V9368 TUBE AS Caterpillar parts 235, 235B TUBE
Rating:
Alternative (cross code) number:
CA9V9368
9V-9368
9V9368
CA9V9368
9V-9368
9V9368
Weight: 2 pounds 0 kg.
Buy TUBE AS 9V9368 Caterpillar genuine, new aftermarket tractor parts with delivery
EXCAVATOR,
Information:
Instrument Panel Switches
Illustration 1 g00310265
Instrument Panel Switches (1) Starting Aid Switch (SAS) (optional). (2) Governor Switch (GS) (optional) or Speed Potentiometer (SP) (optional). (3) Panel Light Switch (PLS) (optional). (4) Engine Control Switch (ECS). (5) Voltage Adjust Rheostat (VAR). (6) Emergency Stop Push Button (ESPB). The engine control switch (ECS) (4) determines the status of the control panel. In the AUTO position (3 o'clock), the GSC allows the operator to remotely control and monitor the generator set with a Customer Communication Module. See Systems Operation, "Customer Communication Module". Also, the GSC allows the engine to start whenever the remote initiating contact (IC) is closed. The engine also shuts down after the initiate contacts open. A cooldown period is programmable (setpoint P19) in order to give a 0 to 30 minute cooldown period before the engine shuts down. The cooldown period is factory set at five minutes. In the MANUAL START position (6 o'clock), the engine starts and runs as long as the ECS is in this position. In the COOLDOWN/STOP position (9 o'clock), the fuel solenoid shuts down the engine after the cooldown period. In the OFF/RESET position (12 o'clock), the engine shuts down immediately and any fault indicators are reset except the emergency stop. If the red emergency stop push button (ESPB) (6) is pressed, the fuel is shut off. In order to restart the engine, follow these steps: Turn the ESPB (6) clockwise until the push button releases. Turn the ECS to OFF/RESET and then turn the ECS to MANUAL START.The voltage adjust rheostat (VAR) (5) is used to adjust the generator voltage to the desired level.The optional governor switch (GS) (2) is used to change the engine speed when the governor has a speed adjust motor. If an electronic governor is used, a speed adjust potentiometer (SP) is mounted in this location. The optional panel light switch (PLS) (3) turns the panel lamps ON and OFF. The optional starting aid switch (SAS) (1) is present only on required gensets. Two types of starting aid systems exist. Manual - This type is used for metered shot starting aid systems. Automatic - This type is used for continuous flow starting aid systems (3500 engines only).On manual starting aid types, when SAS (1) is placed and held in the ON position, the metered shot starting aid system is activated. A specific amount of ether is metered into a holding chamber. When SAS (1) is released, a solenoid allows ether to flow to the engine. The metered shot starting aid system deactivates when any of the following events occur:
The contacts of the crank termination relay (CTR) open at an engine speed of approximately 400 rpm.
The engine coolant temperature is sufficient to open the start aid temperature switch (SATS).
The SAS (1) is released to the OFF position.
Crank the engine before activating (keep SAS in OFF position) the metered shot start aid system. Damage to the engine is possible by activating the system when the engine is not turning.
On automatic starting aid
Illustration 1 g00310265
Instrument Panel Switches (1) Starting Aid Switch (SAS) (optional). (2) Governor Switch (GS) (optional) or Speed Potentiometer (SP) (optional). (3) Panel Light Switch (PLS) (optional). (4) Engine Control Switch (ECS). (5) Voltage Adjust Rheostat (VAR). (6) Emergency Stop Push Button (ESPB). The engine control switch (ECS) (4) determines the status of the control panel. In the AUTO position (3 o'clock), the GSC allows the operator to remotely control and monitor the generator set with a Customer Communication Module. See Systems Operation, "Customer Communication Module". Also, the GSC allows the engine to start whenever the remote initiating contact (IC) is closed. The engine also shuts down after the initiate contacts open. A cooldown period is programmable (setpoint P19) in order to give a 0 to 30 minute cooldown period before the engine shuts down. The cooldown period is factory set at five minutes. In the MANUAL START position (6 o'clock), the engine starts and runs as long as the ECS is in this position. In the COOLDOWN/STOP position (9 o'clock), the fuel solenoid shuts down the engine after the cooldown period. In the OFF/RESET position (12 o'clock), the engine shuts down immediately and any fault indicators are reset except the emergency stop. If the red emergency stop push button (ESPB) (6) is pressed, the fuel is shut off. In order to restart the engine, follow these steps: Turn the ESPB (6) clockwise until the push button releases. Turn the ECS to OFF/RESET and then turn the ECS to MANUAL START.The voltage adjust rheostat (VAR) (5) is used to adjust the generator voltage to the desired level.The optional governor switch (GS) (2) is used to change the engine speed when the governor has a speed adjust motor. If an electronic governor is used, a speed adjust potentiometer (SP) is mounted in this location. The optional panel light switch (PLS) (3) turns the panel lamps ON and OFF. The optional starting aid switch (SAS) (1) is present only on required gensets. Two types of starting aid systems exist. Manual - This type is used for metered shot starting aid systems. Automatic - This type is used for continuous flow starting aid systems (3500 engines only).On manual starting aid types, when SAS (1) is placed and held in the ON position, the metered shot starting aid system is activated. A specific amount of ether is metered into a holding chamber. When SAS (1) is released, a solenoid allows ether to flow to the engine. The metered shot starting aid system deactivates when any of the following events occur:
The contacts of the crank termination relay (CTR) open at an engine speed of approximately 400 rpm.
The engine coolant temperature is sufficient to open the start aid temperature switch (SATS).
The SAS (1) is released to the OFF position.
Crank the engine before activating (keep SAS in OFF position) the metered shot start aid system. Damage to the engine is possible by activating the system when the engine is not turning.
On automatic starting aid
Caterpillar parts catalog:
Parts tube Caterpillar catalog:
2P2547
TUBE AS-GUIDE
120G, 12G, 12H, 12H ES, 12H NA, 130G, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 235, 3304B, 3306, 515, 518C, 525, 528B, 530B, 572G, 936, 936F, 950, 966R, ...
120G, 12G, 12H, 12H ES, 12H NA, 130G, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 235, 3304B, 3306, 515, 518C, 525, 528B, 530B, 572G, 936, 936F, 950, 966R, ...
8N7318
TUBE AS
120B, 120G, 12G, 12H, 12H ES, 12H NA, 130G, 140B, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 1673C, 235, 235B, 330, 330 L, 3304, 3304B, 3306, 3306B, 3306C,...
120B, 120G, 12G, 12H, 12H ES, 12H NA, 130G, 140B, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 1673C, 235, 235B, 330, 330 L, 3304, 3304B, 3306, 3306B, 3306C,...
8N7315
TUBE AS-OUTLET
120B, 120G, 12G, 12H, 12H ES, 12H NA, 130G, 140B, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 1673C, 235, 235B, 330, 330 L, 3304, 3304B, 3306, 3306B, 3306C,...
120B, 120G, 12G, 12H, 12H ES, 12H NA, 130G, 140B, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 1673C, 235, 235B, 330, 330 L, 3304, 3304B, 3306, 3306B, 3306C,...
2P1739
TUBE AS-PUMP
12G, 12H, 12H ES, 12H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 235, 235B, 235C, 330, 330 L, 3306, 3306B, 3306C, 330B, 330B L, 350, 528B, 530B, 545, 5...
12G, 12H, 12H ES, 12H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 235, 235B, 235C, 330, 330 L, 3306, 3306B, 3306C, 330B, 330B L, 350, 528B, 530B, 545, 5...
4W4211
TUBE AS-FUEL FILTER
235, 235C, 3306
235, 235C, 3306
2P2519
TUBE ASSEM.
120B, 120G, 140B, 1673C, 215, 235, 3304, 3306, 627B, 920, 941, 950, 951B, 955L, 966C, 977K, D4D, D4E, D5, D5B, D6C, D7F, D7G, G3304, G3306
120B, 120G, 140B, 1673C, 215, 235, 3304, 3306, 627B, 920, 941, 950, 951B, 955L, 966C, 977K, D4D, D4E, D5, D5B, D6C, D7F, D7G, G3304, G3306
5P1010
TUBE .25m(10 in.)
16G, 215, 215B, 225, 227, 235, 245, 245B, 312B, 315B, 320, 320 L, 320B, 320B FM LL, 320B L, 320B U, 320C, 320N, 322, 322 L, 322B, 322B L, 325, 325B, 325B L, 325C L, 330, 330 L, 3306, 330B, 330B L, 345...
16G, 215, 215B, 225, 227, 235, 245, 245B, 312B, 315B, 320, 320 L, 320B, 320B FM LL, 320B L, 320B U, 320C, 320N, 322, 322 L, 322B, 322B L, 325, 325B, 325B L, 325C L, 330, 330 L, 3306, 330B, 330B L, 345...
5V6118
TUBE ASSEM.
225, 235
225, 235
4V8195
TUBE ASSEM.
235, 235B
235, 235B
4V5965
TUBE ASSEM.
235, 235B, 235C
235, 235B, 235C
8V9147
TUBE AS
235
235
6W9415
TUBE AS
235, 235B, 235C, 235D
235, 235B, 235C, 235D
6W9409
TUBE AS
235, 235B, 235C, 235D
235, 235B, 235C, 235D
8V9399
TUBE AS
235, 235B, 235C, 235D
235, 235B, 235C, 235D
8V8543
TUBE AS
235, 235B
235, 235B
9V8292
TUBE AS
245, 245B
245, 245B
9V7686
TUBE AS
245, 245B
245, 245B
6W9429
TUBE AS
235B, 235C, 235D
235B, 235C, 235D
6W7031
TUBE AS
235, 235B, 235C, 235D
235, 235B, 235C, 235D
6W7032
TUBE AS
235, 235B
235, 235B
8V9401
TUBE AS
235, 235B, 235C, 235D
235, 235B, 235C, 235D
9V9367
TUBE AS
235, 235B, 235C, 235D
235, 235B, 235C, 235D