9W0471 TUBE AS Caterpillar parts D10N, D9L TUBE
Rating:
Alternative (cross code) number:
CA9W0471
9W-0471
9W0471
CA9W0471
9W-0471
9W0471
Weight: 8 pounds 3 kg.
Buy TUBE AS 9W0471 Caterpillar genuine, new aftermarket tractor parts with delivery
TRACK-TYPE TRACTOR,
Information:
Illustration 4 g02355127
(13) USB data output active (14) Differential Pressure Mode (15) Data Hold Mode (16) Primary display (17) Record Mode (18) MAX/MIN/AVG indicators (19) Low Battery Indicator (20) Pressure unit of measure (21) Elapsed TimerSetup And Operation
Setup
Illustration 5 g02370567
Note: The meter must be set to the inches H2O mode.Note: The overall system accuracy for the intended use is 20%.Choose the proper orifice for your application.The Small Orifice (A) is for use with engines with 400 hp and less. The Large Orifice is for engines with greater than 400 hp.Once a reading of inches is obtained with the meter, convert to cfm using the charts in section titled ""Charts"" in this manual. There are charts for engines 400 hp and less, and engines over 400 hp.Operation
Obtain a reading of inches H2O with meter.Note: Do Not use the MIN/MAX AVG function for this reading.
Convert reading to Cubic Feet Per Minute (CFM) using the charts in section titled ""Charts"" in this manual. There are charts for engines 400 hp and less, and engines over 400 hp.
Multiply CFM by 60 (CFM x 60) to convert to Cubic Feet Per Hour.Charts
Illustration 6 g02366736
Engines 400 hp and less
Illustration 7 g02366737
Engines 400 hp and greaterMeter Power
The 368-8645 Tool Kit (CRANKCASE PRESSURE) uses a 9V battery for power. If the meter does not switch on when the "POWER" button is pressed or if the display shows "BAT", replace the battery.When the "POWER" button is pressed, the meter performs a short self-test and reverts to the settings in place when the meter was last turned off.Automatic Power-off Feature
In order to conserve battery life, the meter has an automatic power-off feature (after 20 minutes). To defeat this feature, press and hold the "HOLD/ZERO" (9) button while turning the meter on. Release the "HOLD/ZERO" (9) button when "'n'" appears on the display. The meter will now remain on until the user turns the meter off or until the battery weakens. The Auto Power OFF feature will be reactivated the next time the meter is turned off and then on.Fittings Connection
Connect tubing to the P1 (3), P2 (1) (or both) input ports. If both inputs are used (differential mode), the meter displays a positive pressure reading if the P1 (3) pressure is greater than P2 (1) and a negative reading if P2 (1) is greater than P1 (3) .Zero Adjust and Offset function
To ZERO the meter, before use and without fittings attached to the meter, press and hold the "HOLD/ZERO" (9) button for 3 seconds or until the display shows all zeros (0000) then "0.00".To OFFSET meter readings: Press the "DIF" (7) button while taking a measurement. Subsequent readings will represent the difference between the current measurement and the measurement that was on the display when the "DIF" (7) button was pressed.MIN-MAX-AVG Record Mode with Elapsed Timer
The "RECORD" (8) function tracks the maximum "MAX" (6), minimum "MIN" (18), and average "AVG" (18) readings with a time stamp. The elapsed timer is displayed on the lower right-hand corner of the LCD. The elapse
Caterpillar parts catalog:
Parts tube Caterpillar catalog:
7X2049
TUBE AS-REFRIGERANT ORIFICE
120H, 120H ES, 120H NA, 12H, 12H ES, 12H NA, 135H, 135H NA, 140H, 140H ES, 140H NA, 143H, 14H, 14H NA, 160H, 160H ES, 160H NA, 163H, 163H NA, 16H, 307B, 317B LN, 318B, 322B L, 325B L, 330B L, 345B, 34...
120H, 120H ES, 120H NA, 12H, 12H ES, 12H NA, 135H, 135H NA, 140H, 140H ES, 140H NA, 143H, 14H, 14H NA, 160H, 160H ES, 160H NA, 163H, 163H NA, 16H, 307B, 317B LN, 318B, 322B L, 325B L, 330B L, 345B, 34...
5P0078
TUBE
3204, 3408, 416D, 416E, 420D, 420E, 424D, 428D, 430E, 432D, 442D, 936F, D6N, D9L, IT28, R3000H
3204, 3408, 416D, 416E, 420D, 420E, 424D, 428D, 430E, 432D, 442D, 936F, D6N, D9L, IT28, R3000H
1073202
TUBE AS
24H, 3408E, 3412E, 5110B, 631D, 631E, 631G, 633E II, 637E, 637G, 651E, 657E, 69D, 769C, 769D, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 834B, 836, 844, 988B, 988F II, 990, 990 II, 992C, AD40, AD45, AE...
24H, 3408E, 3412E, 5110B, 631D, 631E, 631G, 633E II, 637E, 637G, 651E, 657E, 69D, 769C, 769D, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 834B, 836, 844, 988B, 988F II, 990, 990 II, 992C, AD40, AD45, AE...
9Y2148
TUBE AS-EXHAUST
3408, 3412, 589, 631E, 637E, 651E, 657E, D10N, D8L, D9N, D9R
3408, 3412, 589, 631E, 637E, 651E, 657E, D10N, D8L, D9N, D9R
9Y2149
TUBE AS-EXHAUST
3408, 3412, 589, 631E, 637E, 651E, 657E, D10N, D8L, D9N, D9R
3408, 3412, 589, 631E, 637E, 651E, 657E, D10N, D8L, D9N, D9R
9Y2151
TUBE AS-EXHAUST
589, 631E, 637E, 657E, D10N, D8L, D9N, D9R
589, 631E, 637E, 657E, D10N, D8L, D9N, D9R
9Y2150
TUBE AS-EXHAUST
589, 631E, 637E, 657E, D10N, D8L, D9N, D9R
589, 631E, 637E, 657E, D10N, D8L, D9N, D9R
1049549
TUBE AS
589, D10N, D9N, D9R
589, D10N, D9N, D9R
1215459
TUBE AS-EXHAUST
631E, 633E II, 637E, 651E, 657E, D10N, D10R, D8L, D9L, D9N, D9R
631E, 633E II, 637E, 651E, 657E, D10N, D10R, D8L, D9L, D9N, D9R
1215461
TUBE AS-EXHAUST
631E, 633E II, 637E, 651E, 657E, D10N, D10R, D8L, D9L, D9N, D9R
631E, 633E II, 637E, 651E, 657E, D10N, D10R, D8L, D9L, D9N, D9R
1215455
TUBE AS-EXHAUST
631E, 633E II, 637E, 651E, 657E, D10N, D10R, D8L, D9L, D9N, D9R
631E, 633E II, 637E, 651E, 657E, D10N, D10R, D8L, D9L, D9N, D9R
1W5651
TUBE AS-EXHAUST
651E, 657E, D8L, D9L
651E, 657E, D8L, D9L
9W9008
TUBE AS
825C
825C
9W5166
TUBE AS
D7H
D7H
3G9357
TUBE AS
D9L
D9L
9W6364
TUBE AS
D7H
D7H
9W7987
TUBE AS
D8N
D8N
4T7466
TUBE AS
D8L
D8L
9W2892
TUBE AS
D10N
D10N
9W2876
TUBE AS
D10N
D10N
9W2891
TUBE AS
D10N
D10N
9W2875
TUBE AS
D10N
D10N
6Y0932
TUBE AS
D8N
D8N