9W0345 VANE-ACTUATOR Caterpillar parts 65, 65C, 65E, 75C, 75D, 75E, 85C, 85D, 85E, 95E VANE
Rating:
Alternative (cross code) number:
CA9W0345
9W-0345
9W0345
CA9W0345
9W-0345
9W0345
Weight: 0.20 pounds 0 kg.
Buy VANE-ACTUATOR 9W0345 Caterpillar genuine, new aftermarket tractor parts with delivery
CHALLENGER,
Information:
Illustration 1 g01324428
Schematic for the Pilot Pressure Solenoid ValveThis diagnostic code is recorded when the ECM detects a short to the +battery in the electrical path that goes from the ECM to the solenoid back to the ECM. The possible causes for this diagnostic code are listed:
The signal circuit from the ECM to the solenoid is shorted to the +battery.
The return circuit from the solenoid is shorted to the +battery.Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.System Response:The machine response is listed:
The implement hydraulic operation is disabled by the machine ECM.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the original diagnostic code is corrected. Note: Ensure that the diagnostic code is active and that the diagnostic code indicator is active. Test Step 1. CHECK THE SOLENOID.
Turn the key start switch to the OFF position.
Disconnect the solenoid with the diagnostic code from the harness.
Turn the key start switch to the ON position.
Place all levers in the HOLD position.
At the harness connector for the solenoid, measure the voltage from the ECM between contact 1 (wire E918-GN) and contact 2 (wire H708-OR).Note: This test causes the ECM to log an open circuit diagnostic code for this solenoid. Clear this code from the ECM after troubleshooting. Expected Result: The voltage is approximately 2.5 DCV.Results:
YES - The voltage is approximately 2.5 DCV.Repair: The solenoid has failed. Replace the solenoid.STOP
NO - The voltage is approximately battery voltage. Proceed to Test Step 2.Test Step 2. CHECK THE HARNESS.
Turn the key start switch to the OFF position.
Disconnect the harness from the ECM.
Turn the key start switch to the ON position.
At the harness connector for the ECM, measure the voltage between contact J2-4 (wire H708-OR) and contact J2-2 (wire E918-GN).Expected Result:The voltage is approximately battery voltage.Results:
YES - The voltage is approximately battery voltage.Repair: There is a short to the +battery in the harness. Repair the harness or replace the harness.STOP
NO - The voltage is approximately 0 DCV. The cause or the diagnostic code has not been found. Proceed to Test Step 3.Test Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Turn the key start switch to the OFF position.
Inspect all harness connectors and reconnect.
Turn the key start switch to the ON position.
Operate the machine.
Ensure that the diagnostic code is active.Expected Result:The diagnostic code is active.Results:
YES - The diagnostic code is active.Repair: Check the circuit again.If the cause of the problem is not found, contact the Technical Communicator for your dealership for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the ECM requires replacement, see Troubleshooting, "Electronic Control Module (ECM) - Replace".STOP
NO - The diagnostic code
Caterpillar parts catalog:
Parts vane Caterpillar catalog:
8D2660
VANE PUMP
621, 627
621, 627
2L9126
VANE & SPRING
D397D
D397D
2L0605
VANE
D326F
D326F
3F3896
VANE ASSEM.
D326F, D337, D364, D397D
D326F, D337, D364, D397D
9F7838
VANE
D315, D337, D364, D397D
D315, D337, D364, D397D
2L7736
VANE
3306, 769, D326F, D333B, D334, D342, D342C
3306, 769, D326F, D333B, D334, D342, D342C
7L7465
VANE
772, D348, D353C, D379A